Split Wall Mounted Explosion Proof Air Conditioner

Split Wall Mounted Explosion Proof Air Conditioner

Quick Details

- Split Wall Mounted Explosion Proof Air Conditioner
- For place zone 1&2 where with explosive gas of II A, II B categories, T1 ~ T4 combustible gas, steam and air mixture for petroleum, chemical, military, pharmaceutical, warehousing and other dangerous gas environment in the industry.
- Obtained Explosion-proof certificate from China National Quality Supervision and Inspection Center
- Explosion-proof mark Ex d ib mb IIB T4 Gb or Ex d ib mb IIC T4 Gb.

Get A Quote

Fax: 0086-377-63235296
Tel: 0086-377-61171097
Mail: yitongex001@126.com

Split Wall Mounted Explosion Proof Air Conditioner is mainly used in place zone 1&2 where with explosive gas of II A, II B categories, T1 ~ T4 combustible gas, steam and air mixture. It has obtained Explosion-proof certificate from China National Quality Supervision and Inspection Center. Explosion-proof mark Ex d ib mb IIB T4 Gb or Ex d ib mb IIC T4 Gb.

It can be used for petroleum, chemical, military, pharmaceutical, warehousing and other dangerous gas environment in the industry. the full range, a high temperature, high temperature type, low temperature, marine and other varieties to meet different user requirements.

There are grade IIB and IIC explosion-proof rating to choose from, in accordance with the latest d type explosion-proof design and manufacturing technology, safe, reliable, more secure quality.

Power source optional : 220V-50Hz, 110V-60Hz, 208V-60Hz.

Using internationally renowned brand compressor, stable and reliable operation, energy saving, long service life.

Use high efficient heat exchangers and automatic operation mode, with multiple protection, fault self-diagnosis, intelligent frost, low temperature start-up and timing and other humanized functions.

It looks beautiful, easy to operate, space-saving, easy to install. Products has been strictly tested before leaving the factory to ensure quality. Air conditioning has sufficient refrigerant charge, configured to connect brass and cables, the user simply connect the refrigerant brass and control, power wiring, you can put into operation.

ABOUT US

Nanyang Yitong Explosion proof Electric Co., Ltd. is an advanced electrical solution provider for hazardous areas of zone1, zone 2, and zone 20, zone 21, zone 22.

We have wide range explosion proof products of air conditioners, electrical control box, CCTV camera, lamp & light fixtures, electrical equipments, and box & fittings. Our products and projects occur in various occasions of petroleum, chemical and workshop across the world.We care the most of quality and stability of our products, as well as efficient communication and positive service to our customers and partners.
Most of our products are certified under China explosion protection standards GB3836 series, which is based on International Electrotechnical Commission (IEC) Standard for Electrical Products used in Explosive Environments (Ex), some products also obtained the EU standard certificates as ATEX, IEC Ex, CCS( China explosion proof electric products for Marine environment), MA(for Mine use, China). Company run with ISO quality management system as ISO9001, ISO14001, OHSAS18001 and China QS .
 
Nanyang Yitong is the registered supplier of China National Offshore Oil Corporation(COOC), China National Petroleum Corporation(CNPC), China Oilfield Services Limited(COSL), ABB(Switzerland),
Altrad Group(France), Hyundai Engineering Co., Ltd(Korea).etc. and we have exported many of explosion proof air conditioners and HVAC in Northeast Asia, Australia. We also have solo agent in UAE, Egypt, Russia and Korean.

Packing & Delivery

Production

Manufacturer Qualification

Typical Cases

Exhibitions

FAQ

· Can you design a custom explosion proof solution for me?

Yes! We have team engineers and designers that create custom solutions for our clients daily. 

Just contact  email us as shown.

· What is explosion proof, and how do I determine what best suits my needs?

The term “Explosion proof” is a generic term. Under the IEC, you will need to identify the following items for classification of your unit: Zones, Group(s) and T-Code (surface max. temperatures). For help with this, our company have the pre-sales service team  that will help with your selection. If you need additional help on this matter, please call us. We look forward to hearing from you. Please note that cost and delivery can sometimes be effected by the classification of your unit. Please confirm that your selection is correct for both safety and delivery issues.

· How do I get the unit shipped to my location?

Simple. we can work with your freight forwarder or contract delivery of your units to a  destination of your choice.we can ship your projects by land, sea, or air to any part of the world. we works closely with the best freight forwarders to get your project not only delivered on time, but also undamaged. 

Our shipping team can offer air or sea crating for your projects to keep the equipment in perfect working order. 

· Do you ship equipment to the middle east?

Yes, we ship orders worldwide.

Contact US